Part Number Hot Search : 
LM358QT 300UR100 EL7501CN AX7501M M1MA15 LP28300 MS256 D1086V33
Product Description
Full Text Search
 

To Download SCL1700 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 Preliminary
SCL1700 Series
Inclinometer Subassembly
FEATURES * Available range: 10 * DC...3 Hz sensing bandwidth (controlled frequency response) * Easy to use and design in * 0.001 resolution analogue output * 0.2 accuracy * Dual axis inclination measurement * Advanced failure detection BENEFITS * Excellent long term stability * Sensing element filtered high frequency vibration * Outstanding shock durability APPLICATIONS * Platform tilt measurement * Equipment and instrument condition monitoring * Inclination based position measurement
For customized product please contact VTI Technologies
ELECTRICAL CHARACTERISTICS
Parameter
Supply voltage Output load Operating temperature Mechanical shock 1 m drop on concrete
(1
Condition
Min
7
Typ.
15 4.5 T.B.D T.B.D.
Max
28
Units
V mA kOhm nF
Current consumption Resistive Capacitive -40
85 20 000
C g
PERFORMANCE CHARACTERISTICS
Parameter
Measuring range (1 Measuring axis Offset(2,3 Offset calibration error (3,4 Offset temperature error (3,5 Sensitivity (3,6 Sensitivity calibration error(3,7 Sensitivity temperature error(3,8 Nonlinearity (9 Frequency responce -3 dB Output noise DC...10 Hz 0...70 C -25...85 C 0...70 C -25...85 C @ 0 (offset position) (See "Directions") Output at 0
Condition
SCL1700-D01
10 X-Y 2.5 0.1 0.2 1 200 1 0.5 1 0.03 1...3 0.001
Units
V mV/ % % % Hz
Typical values @ room temperature, 15 V supply unless otherwise specified.
Note 1. Note 2. Note 3. Note 4. Note 5.
Note 6.
The measuring range is limited by sensitivity, offset and supply voltage rails of the device. Offset specified as Voffset = Vout(@0 ) [V]. +15 V supply voltage used in calibration and testing. Offset calibration error specified as Offset_Calib_error = arcsin(Offset_Calib_error_in_g) [ ], Offset_Calib_error_in_g = {Vout(@0 ) - 2.5 V} / Vsens [g], Vsens=11.46 V/g. Offset temperature error specified as Offset_Error_@_temp. = arcsin(Offset_Error_@_temp_in_g) [ ], Offset_Error_@_temp_in_g = {Vout @ temp. - Vout @ room temp.} / Vsens [g], Vsens=11.46 V/g. Sensitivity target in calibration Vsens _nom 11.46 V/g (--> 200 mV/) Sensitivity specified as Vsens = {Vout(@+10 ) - Vout(@+10 )}/(2*sin(10 ) g) [V/g].
Note 7.
Note 8. Note 9.
Sensitivity calibration error specified as Sensitivity_calibr_error = {Vsens - Vsens_nom} / Vsens_nom x 100 % [%], Vsens_nom = nominal sensitivity. Sensitivity temperature error specified as Sensitivity_temp_error = {Vsens @ temp - Vsens @ room temp} / Vsens @ room temp} x 100 % [%]. From best fit sine-function to output through -10 and +10 .
Rev. 10 Sept 2004
VTI Technologies reserves the right to modify this specification without prior to notice.
SCL1700 Series
MEASURING DIRECTIONS
Connector + Sensor y-axis
OUTPUT SIGNAL
-
Earth's gravity
x-axis Notes: * It is important that the part is mounted horizontally. Measuring axes are X and Y according to above figure. * Above figures provide information on how the output of the inclinometer behaves in different circumstances. Please also note that you can rotate the part around the measuring plane for optimum mounting location.
+
ELECTRICAL CONNECTION
Name
Vcc NC GND OutX OutY NC
Fuction
Power supply, 7 - 28 V Internally not connected Ground Analoque X-direction output Analoque Y-direction output Internally not connected
Connector pin
1 2 3 4 5 6
Connector: Molex, Pcoflex PF-50
MECHANICAL SPECIFICATIONS
* * * * * * * PCB Material: PCB thickness: Size: Height: Mounting holes: Weight: Connector: FR4 1.6 mm 45 mm x 45 mm max 10 mm O 3.5 mm < 10 g Molex, Picoflex PF-50, 1.27 mm pitch, mates with Molex 90327
45.00 mm 38.00 mm
45.00 mm
38.00 mm
Pin# 1 Pin# 6
Mechanical dimensions in mm.
MOUNTING
The sensor module is to be mounted with 4 screws, dimension M3.
VTI Technologies Oy Myllynkivenkuja 6 P.O. Box 27 FI-01621 Vantaa Finland Tel. +358 9 879 181 Fax +358 9 879 18791 sales@vti.fi
VTI Technologies Oy Frankfurt Branch Rennbahnstr. 72-74 D-60528 Frankfurt am Main Germany Tel. +49 69 6786 880 Fax +49 69 6786 8829 sales.de@vti.fi
VTI Technologies, Inc. One Park Lane Blvd. Suite 804 - East Tower Dearborn, MI 48126 USA Tel. +1 313 425 0850 Fax +1 313 425 0860 sales@vtitechnologies.com